1. Matters needing attention when using and operating the automatic terminal machine:
When operating the terminal machine, you need to pay attention to the safety of operation. If the machine is abnormal during the operation, turn off the power first, and ask the mechanic to repair and debug it in time. Non-designated personnel are strictly forbidden to debug or disassemble the machine parts without permission. During maintenance and debugging, the power of the machine must be turned off to prevent safety problems during maintenance.
After cleaning the terminal machine after use, the operator must clean the machine every day to remove debris, dust and excess oil on the surface of the machine; when using the machine, if it is found that the stamping guide rail of the terminal machine is not lubricated, we can add oil lubrication once every 1-2 hours , The oiling hole is on the top of the terminal machine, do not add too much oil each time, 2-3 drops is appropriate; at the same time, the main speed bearing of the terminal machine must be greased every week: maintenance during such use is the most important.
2. Solutions to common faults of automatic double-head terminal machine
The emergence of the fully automatic double-ended terminal machine, the new energy vehicle wiring harness equipment, realizes the processing functions of feeding, cutting, multi-function machine stripping, and crimping together. Applicable to various enterprises, it is one of the important equipments to save labor and reduce production costs. The automatic double-ended terminal machine will inevitably have some faults in use. We have sorted out the corresponding solutions for simple fault problems.
1. The clutch of the terminal machine is not positioned, and the motor cannot be started if it is stuck. Possible improper operation and bad mold.
Reason: It is ruled out that the slider is manually operated, the opening handle is pushed in, the spindle is rotated, and the opening wrench is used to put it in.
2. The motor and pulley are running normally and the machine cannot work.
Reason: The terminal electromechanical magnet is bad, replace it with a new one. The electrical circuit board of the automatic double-terminal terminal machine is faulty, and it needs to be replaced. The foot switch of the terminal machine is defective, replace it with a new one.
3. The mute terminal machine cannot work or there is continuous play.
Reason: Mostly because the inverter is faulty or a new pedal is replaced, and the continuous hitting situation may be caused by the insensitivity of the sensing block or the long sensing distance.
4. The mold is stuck and cannot slide up and down
Reason: Rotate the pulley by hand to make the main shaft drive the slide to drive the punch, check whether the upper and lower riveting is bruised or not.